Skip to content

EarthFaultCompensator

A conducting equipment used to represent a connection to ground which is typically used to compensate earth faults. An earth fault compensator device modelled with a single terminal implies a second terminal solidly connected to ground. If two terminals are modelled, the ground is not assumed and normal connection rules apply.

URI: cim:EarthFaultCompensator
Type: Class

 classDiagram
    class EarthFaultCompensator
    click EarthFaultCompensator href "../EarthFaultCompensator"
      ConductingEquipment <|-- EarthFaultCompensator
        click ConductingEquipment href "../ConductingEquipment"


      EarthFaultCompensator <|-- GroundingImpedance
        click GroundingImpedance href "../GroundingImpedance"
      EarthFaultCompensator <|-- PetersenCoil
        click PetersenCoil href "../PetersenCoil"


      EarthFaultCompensator : Equipment.aggregate

      EarthFaultCompensator : ConductingEquipment.BaseVoltage

          EarthFaultCompensator --> BaseVoltage : ConductingEquipment.BaseVoltage
          click BaseVoltage href "../BaseVoltage"

      EarthFaultCompensator : IdentifiedObject.description

      EarthFaultCompensator : IdentifiedObject.energyIdentCodeEic

      EarthFaultCompensator : Equipment.EquipmentContainer

          EarthFaultCompensator --> EquipmentContainer : Equipment.EquipmentContainer
          click EquipmentContainer href "../EquipmentContainer"

      EarthFaultCompensator : IdentifiedObject.mRID

      EarthFaultCompensator : IdentifiedObject.name

      EarthFaultCompensator : Equipment.normallyInService

      EarthFaultCompensator : Equipment.OperationalLimitSet

          EarthFaultCompensator --> OperationalLimitSet : Equipment.OperationalLimitSet
          click OperationalLimitSet href "../OperationalLimitSet"

      EarthFaultCompensator : IdentifiedObject.shortName

      EarthFaultCompensator : ConductingEquipment.Terminals

          EarthFaultCompensator --> Terminal : ConductingEquipment.Terminals
          click Terminal href "../Terminal"

Inheritance

Attributes

Name URI Cardinality and Range Description Inheritance
BaseVoltage cim:ConductingEquipment.BaseVoltage 0..1
BaseVoltage
Base voltage of this conducting equipment ConductingEquipment
Terminals cim:ConductingEquipment.Terminals *
Terminal
Conducting equipment have terminals that may be connected to other conducting... ConductingEquipment
aggregate cim:Equipment.aggregate 0..1
boolean
The aggregate flag provides an alternative way of representing an aggregated ... Equipment
normallyInService cim:Equipment.normallyInService 0..1
boolean
Specifies the availability of the equipment under normal operating conditions Equipment
EquipmentContainer cim:Equipment.EquipmentContainer 0..1
EquipmentContainer
Container of this equipment Equipment
OperationalLimitSet cim:Equipment.OperationalLimitSet *
OperationalLimitSet
The operational limit sets associated with this equipment Equipment
description cim:IdentifiedObject.description 0..1
string
The description is a free human readable text describing or naming the object IdentifiedObject
energyIdentCodeEic eu:IdentifiedObject.energyIdentCodeEic 0..1
string
The attribute is used for an exchange of the EIC code (Energy identification ... IdentifiedObject
mRID cim:IdentifiedObject.mRID 1
string
Master resource identifier issued by a model authority IdentifiedObject
name cim:IdentifiedObject.name 1
string
The name is any free human readable and possibly non unique text naming the o... IdentifiedObject
shortName eu:IdentifiedObject.shortName 0..1
string
The attribute is used for an exchange of a human readable short name with len... IdentifiedObject

Identifier and Mapping Information

Schema Source

  • from schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile

Mappings

Mapping Type Mapped Value
self cim:EarthFaultCompensator
native this:EarthFaultCompensator